Smart leak detectors work, within limits. A flow monitor with a shut-off valve on the incoming main is the only type that can stop a burst by itself: it sees water flowing when nothing should be using it and closes the valve. A clip-on monitor warns you about constant flow but cannot shut anything off. Floor sensors only catch water that reaches them. None of them can see a leak on a sealed central heating system, a supply pipe leak before the device, or a waste pipe leaking inside a wall, and none of them tells you where a leak is. That last part is what a leak detection survey is for.
This guide is about devices for a single house or flat. For blocks of flats, offices and plant rooms, see our guide to leak detection systems for buildings.
The Three Types
Flow monitors with a shut-off valve. These are fitted on the rising main just after the stopcock, which is a plumber's job. Grohe Sense Guard is a common example. The unit measures the water passing through it and learns what normal use looks like in your home. It alerts you when water runs for longer than usual or flows faster than usual, and it can close its own valve. Some models also run a short test at night: they close the valve and watch the pressure. If the pressure falls with the valve shut, water is escaping somewhere downstream, even if the leak is tiny.
Clip-on monitors. LeakBot is the best known. It clips onto the cold mains pipe near the stopcock with no plumbing work. It reads the temperature of the pipe rather than the flow. When water is used, the pipe cools towards the temperature of the water coming in. If water never stops flowing, the pipe never warms back up to room temperature, and the device flags it. It warns you, but it has no valve. Some UK home insurers give these devices to their customers.
Floor sensors. Small battery units that sit on the floor and sound an alarm or send a phone notification when they get wet. They know nothing about the plumbing. They are cheap and easy to place, and they are the only type that can catch a leak from something not on the mains, such as a heating pipe or a waste trap, provided the water lands on them.
What Each Type Catches and Misses
| Leak | Flow monitor with valve | Clip-on monitor | Floor sensor |
|---|---|---|---|
| Burst on a mains-fed pipe | Yes, and closes the valve | Warns, cannot close | Only if the water reaches it |
| Pinhole or seeping joint on a mains-fed pipe | Usually, through constant flow or the night pressure test | Yes, constant flow is what it looks for | Only once water pools at the sensor |
| Tap or toilet left running | Yes | Yes | No |
| Sealed central heating leak | No, heating water does not pass through it | No | Only if it drips onto the sensor |
| Supply pipe leak under the garden or pavement | No, the leak is before the device | No | No |
| Waste pipe, shower tray or bath seal | No, waste pipes are not pressurised | No | Only directly under the leak |
| Leak on pipework fed from a loft tank | Sees the tank refilling, but closing the valve does not stop the tank draining | Sees the tank refilling | Only if the water reaches it |
The heating row catches a lot of people out. On a combi or system boiler the heating is a sealed loop, filled once and topped up by hand. A leak on it never shows as water flowing through the main. The sign to watch is the boiler pressure gauge dropping, and the need to top it up more and more often.
Fitting One in a London Home: What to Check First
Where the main comes in. A flow monitor needs a straight, reachable section of pipe after the stopcock. In terraced houses that is often under the kitchen sink or below the floor by the front door. In flats, the stopcock may be on a riser in a communal cupboard, and fitting anything there may need the freeholder's agreement. Some flats are fed from a communal tank rather than the mains, which changes what a flow monitor can see.
Whether you have a loft tank. In tank-fed houses the valve protects the mains-fed pipework, usually the kitchen cold tap and the tank's own supply. The pipework fed from the tank still holds whatever is in the tank. Add a floor sensor under the tank and another beside the hot water cylinder.
The heating. Put a sensor under the boiler and, if you have underfloor heating, under the manifold. Check the boiler pressure gauge once a week and note the reading.
The age of the supply pipe. A lead or galvanised steel main may need a short section replaced before a valve can be fitted. That is worth doing anyway.
Floor sensors go at the lowest point where water would collect: under the kitchen sink, behind the washing machine and dishwasher, under the boiler, next to the cylinder, under the bath panel at the low end, and in the loft below the cold tank. A sensor on a shelf or a raised plinth will not see a thing.
When an Alert Goes Off
First rule out the obvious: a tap left on, a toilet cistern that keeps refilling, a garden hose. If nothing is running, read the water meter, wait an hour without using any water, and read it again. A meter test also tells you how fast the leak is losing water, which is useful when you call.
Then close the internal stopcock and repeat the test. If the meter still moves with the stopcock closed, the leak is on the supply pipe between the meter and the house. If it stops, the leak is inside, somewhere on the pipework after the stopcock. Either way, the device has told you that you have a leak, not where it is. Finding the exact point under a floor or behind a wall needs specialist detection equipment, so the repair is one small opening rather than lifting a whole room.
Limits Worth Knowing
Flow monitors and app-based sensors need power and Wi-Fi to send alerts. A power cut or a dropped connection can leave you without warnings, although a valve set to close on its own may still work. Battery sensors need fresh batteries, and a flat battery looks exactly like a dry floor.
Automatic valves can close when there is no leak. Filling a bath, running a hose or a long shower can look like a burst to a system that has learned your usual pattern. Most let you adjust the sensitivity and pause protection, but expect to tune it in the first few weeks.
Is It Worth Fitting One?
The case is strongest where a leak would run for a long time before anyone noticed: homes left empty during the week or over holidays, flats above other flats, and houses with a lot of pipework buried under floors. A few floor sensors cost little and take minutes to place. A flow monitor with a valve costs more and needs a plumber, but it is the only option that turns a burst into a short interruption instead of a ceiling coming down. Whichever you choose, it reduces how long a leak runs. It does not replace a survey when a leak is somewhere you cannot see.