Underfloor Heating Leak Detection: How Engineers Find the Leak

7 min read

The engineer pressure tests each loop at the manifold to find the leaking one, runs that loop warm and thermal images the floor, then confirms the spot with tracer gas or acoustic listening if needed.

Under-Floor Leak Detection: £300-£700

Call 020 3912 0200

How is a leak in underfloor heating pipes found?

In three stages, each one smaller than the last. First the loops are pressure tested one at a time at the manifold, which pins the leak to one circuit and usually one room. Then that loop is run warm on its own and the floor is scanned with a thermal camera, which shows the pipe pattern and the warm spread where water is getting out. Where the floor finish or the depth of screed hides the heat, tracer gas or acoustic listening confirms the spot. The result is a mark on the floor precise enough for the repair to need one small opening.

Underfloor heating (UFH) pipe is usually cross-linked polyethylene (PEX) or polybutylene (PB), laid as continuous loops in a sand and cement screed, or in spreader plates between joists on timber floors. The water runs at roughly 35 to 55 degrees Celsius, cooler than radiators, which matters for thermal imaging. Because the loops have no joints under the floor, the engineer looks first wherever something has been fixed down since the heating went in.

If you are still working out whether the floor is the problem at all, our page on what to check when underfloor heating keeps losing pressure covers the gauge readings and loop isolation you can do yourself first.

Stage 1: pressure testing each loop at the manifold

The engineer isolates the manifold from the boiler or heat pump, closes every loop at both ends, and connects a hand test pump and a calibrated test gauge to the manifold fill and drain points. Each loop is then opened in turn, pressurised to the figure in the pipe maker's data, and held. A sound loop holds its pressure. A leaking loop falls.

The test gauge is the point of this stage. A boiler gauge reads in tenths of a bar and a slow leak can take days to move it. A test gauge on a single loop shows a small loss within the hold time, so a weep that the homeowner could only suspect becomes a clear answer. The manifold is tested on its own with all loops closed, and so is the pipework back to the heat source, because leaks on the pump set and mixing valve show up there.

BS EN 1264 calls for circuits to be pressure tested before the screed goes down, so the installer's commissioning sheet, where there is one, records the original test pressure. Testing to the same figure gives a fair comparison. What this stage cannot do is say where in the loop the leak is. A single loop can be tens of metres of pipe snaking across a room.

Stage 2: thermal imaging with the system warm

The leaking loop is refilled and run on its own with the other loops closed, so the camera sees one pattern instead of a whole warm floor. The engineer starts with the floor cold and scans as the heat comes through. The end nearest the manifold warms first, then the warm lines spread across the room following the layout, as a spiral or a serpentine. A leak shows as a warm patch that breaks away from that pattern, hottest at one point and fading outwards as the water spreads through the screed. Beyond a bigger leak, the lines further along the loop can look weaker.

Timing is most of the skill. Scan too early and the pipe pattern has not come through. Scan after hours of running and the whole floor is warm, so small differences wash out. Images are taken at intervals during the warm-up and compared, and a second scan later confirms the first. The floor finish changes how much the camera can see.

Floor finish over the screedHow clearly the pipe pattern showsNotes
Ceramic or stone tilesClearDense, conductive finishes show the loop layout and leaks well
Vinyl, LVT or thin laminateUsually clearGlossy surfaces reflect heat sources, so the angle of view matters
Engineered timberModerateTimber slows and spreads the heat, so the scan takes longer
Carpet and underlayWeakThick underlay insulates the surface. Lifting a corner or another method may be needed
Spreader plates under a timber floorModerateThe plates even out the heat, which can blur a small leak

The thermal images also record the layout as it was actually laid, which often differs from the drawings. That matters for the repair, because cutting into the screed must not damage the neighbouring runs of the same loop.

Stage 3: tracer gas or acoustic listening under thick screed

Sometimes the loop is known to be leaking but the thermal image is inconclusive. Thick screed, carpet and very slow leaks are the usual reasons. Tracer gas is often the better next step for UFH. The leaking loop is drained, filled with a mix of 5% hydrogen and 95% nitrogen, and the engineer sweeps a hydrogen detector along the route mapped in stage 2. The gas comes up through the screed and out at grout lines and joints in the floor finish, and the strongest reading marks the leak. On a sealed finish, a few small sampling holes let the probe read just below the surface.

Acoustic listening has a smaller part to play. Plastic pipe carries sound poorly, so a ground microphone only picks up the leak when it is close to it. It works best once the area is already narrowed and the loop is held at a steady pressure by the test pump. Whichever method finds the spot, a moisture meter confirms the anomaly is water and not a gap in the insulation or a variation in the screed.

What does the survey leave you with?

A mark on the floor over the leak, the leaking loop labelled at the manifold, and a written report with the thermal images, moisture readings and the method that confirmed the position. The report is what a heating engineer needs for the repair and what an insurer will ask to see.

How is the leak repaired once it is marked?

  • Local opening. A small section of floor, typically about 300mm by 300mm, is cut out over the mark. The damaged pipe is cut out, a coupling suited to that pipe type is fitted, and the loop is pressure tested before the screed and finish are made good.
  • Isolating the loop. If the repair would sit under a kitchen island or fitted unit, the loop can be closed at the manifold and abandoned while the rest of the system carries on, and the room heated another way.
  • Replacing the loop. Where the pipe has degraded along its length, the whole loop may need replacing. This is the most disruptive option and is mostly seen on older installations.

Any repair should be done by someone who works on UFH, as the pipes need the right fittings and tools, and the loop must be pressure tested afterwards to prove it is sound.

How much does underfloor heating leak detection cost?

Under-floor leak detection is priced at £300 to £700, depending on the floor area, the number of loops and the methods needed. The report is included. Many home insurance policies cover the cost of finding the leak under trace and access cover, so check your policy before work starts.

Frequently asked questions

Does the heating need to be working for a survey?

For thermal imaging, yes. The leaking loop has to run warm. If the boiler or heat pump is out of action, the engineer relies more on the loop test and tracer gas.

Can thermal imaging find an underfloor heating leak under carpet?

Sometimes, but carpet and underlay block much of the heat. Lifting the carpet along the suspect loop gives a far clearer image, and tracer gas is the fallback.

Will the floor have to come up?

Only over the leak. The aim of the three stages is a single small opening rather than lifting a room.

How we help with this

If the article points at a problem you actually have, these are the surveys that deal with it.

Not sure which one applies? Describe what you can see on the phone and you will be told which survey it is and what it costs, before anything is booked. 020 3912 0200

Written by the Leak Detect London team

Our specialist engineers share practical advice from years of leak detection experience across London. Every article is written by qualified professionals who work on these problems daily.

Free Quote

Get a No-Obligation Leak Detection Quote

Tell us what's happening and we'll come back to you with a clear price for the investigation. No pressure, no hidden fees. Or if it's urgent, just ring us. We pick up 24/7.

Prefer to talk? Call 020 3912 0200
Free
No-obligation quotes
Same-Day
Appointments available
24/7
Emergency response
No Find
No fee guarantee
1Step 1 of 1: Tell us about your leak
What type of issue?
Preferred contact time
No obligation

Need Professional Leak Detection?

Our specialist engineers use thermal imaging, acoustic detection, and tracer gas to locate leaks quickly and accurately across London. Same-day service available.

LEAK DETECTION 24/7020 3912 0200